摘 要:针对目前母线充电保护存在的一些缺点和不足,在分析母线充电机理和过程的基础上,综合利用母线正常充电和故障充电情形下多种电气特征量值的差异,运用模糊超盒分类器来形成区分母线正常充电和故障元件充电的保护判据识别.通过EMTP程序的大量仿真得到模糊超盒网络的训练和检验样本,结果表明,该方法能够快速准确地判别出母线在各种运行工况下的正常充电和故障元件充电.At present the bus anism and processes of bus c charging protections have some disadvantages and shortcomings. Analyzing the mechharging and making full use of the differences of characteristics variables' value between normal bus charging and fault element charging , a new protective method is presented in this paper to distinguish normal bus charging from fault element charging based on the fuzzy hyperbox classifier. EMTP program is used to obtain plenty discriminate normal c of training and testing patterns. The results show that this method can quickly and accurately harging and fauh charging under all kinds of operating conditions.