检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]School of Metallurgy Engineering,Xi'an University of Architecture and Technology
出 处:《过程工程学报》2007年第3期483-489,共7页The Chinese Journal of Process Engineering
基 金:Supported by Natural Science Foundation of China (No.50244012);National Science Foundation of Shaanxi Education Department (No.02JC37)
摘 要:The absorption of low concentration SO2 in flue gas by using the module of liquid-containing microporous membrane which is made up of hollow fiber and citric acid-sodium citrate buffer solution was investigated.The absorption efficiency of hydrophilic and hydrophobic membranes by using the concept of dynamic contact angle was mainly studied.The influences on absorption efficiency from absorption time,flowrate of gas phase,SO2 concentration of gas phase,air pressure,citrate concentration,pH value of solution as well as the generation of sulfate radical in absorption solution were examined.The results indicate that the hydrophobic hollow fiber membrane is better than hydrophilic membrane,the absorption efficiency decreases with increasing absorption time,gas phase flowrate,gas phase SO2 concentration and air pressure,the absorption rate and capacity of SO2 can be improved by increasing the citrate concentration,the absorption efficiency can be improved by increasing the pH value of citrate solution,the concentration of SO42-in absorption solution increases linearly with the absorption time at a rate around 0.192 g/(L-h).The absorption of low concentration SO2 in flue gas by using the module of liquid-containing microporous membrane which is made up of hollow fiber and citric acid-sodium citrate buffer solution was investigated. The absorption efficiency of hydrophilic and hydrophobic membranes by using the concept of dynamic contact angle was mainly studied. The influences on absorption efficiency from absorption time, flowrate of gas phase, SO2 concentration of gas phase, air pressure, citrate concentration, pH value of solution as well as the generation of sulfate radical in absorption solution were examined. The results indicate that the hydrophobic hollow fiber membrane is better than hydrophilic membrane, the absorption efficiency decreases with increasing absorption time, gas phase flowrate, gas phase SO2 concentration and air pressure, the absorption rate and capacity of SO2 can be improved by increasing the citrate concentration, the absorption efficiency can be improved by increasing the pH value of citrate solution, the concentration of SO42- in absorption solution increases linearly with the absorption time at a rate around 0.192 g/(L.h).
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.219.65.132