Absorption of Low Concentration Sulfur Dioxide Using Liquid-containing Microporous Membrane  被引量:5

Absorption of Low Concentration Sulfur Dioxide Using Liquid-containing Microporous Membrane

在线阅读下载全文

作  者:薛娟琴 兰新哲 孟令嫒 李伟达 

机构地区:[1]School of Metallurgy Engineering,Xi'an University of Architecture and Technology

出  处:《过程工程学报》2007年第3期483-489,共7页The Chinese Journal of Process Engineering

基  金:Supported by Natural Science Foundation of China (No.50244012);National Science Foundation of Shaanxi Education Department (No.02JC37)

摘  要:The absorption of low concentration SO2 in flue gas by using the module of liquid-containing microporous membrane which is made up of hollow fiber and citric acid-sodium citrate buffer solution was investigated.The absorption efficiency of hydrophilic and hydrophobic membranes by using the concept of dynamic contact angle was mainly studied.The influences on absorption efficiency from absorption time,flowrate of gas phase,SO2 concentration of gas phase,air pressure,citrate concentration,pH value of solution as well as the generation of sulfate radical in absorption solution were examined.The results indicate that the hydrophobic hollow fiber membrane is better than hydrophilic membrane,the absorption efficiency decreases with increasing absorption time,gas phase flowrate,gas phase SO2 concentration and air pressure,the absorption rate and capacity of SO2 can be improved by increasing the citrate concentration,the absorption efficiency can be improved by increasing the pH value of citrate solution,the concentration of SO42-in absorption solution increases linearly with the absorption time at a rate around 0.192 g/(L-h).The absorption of low concentration SO2 in flue gas by using the module of liquid-containing microporous membrane which is made up of hollow fiber and citric acid-sodium citrate buffer solution was investigated. The absorption efficiency of hydrophilic and hydrophobic membranes by using the concept of dynamic contact angle was mainly studied. The influences on absorption efficiency from absorption time, flowrate of gas phase, SO2 concentration of gas phase, air pressure, citrate concentration, pH value of solution as well as the generation of sulfate radical in absorption solution were examined. The results indicate that the hydrophobic hollow fiber membrane is better than hydrophilic membrane, the absorption efficiency decreases with increasing absorption time, gas phase flowrate, gas phase SO2 concentration and air pressure, the absorption rate and capacity of SO2 can be improved by increasing the citrate concentration, the absorption efficiency can be improved by increasing the pH value of citrate solution, the concentration of SO42- in absorption solution increases linearly with the absorption time at a rate around 0.192 g/(L.h).

关 键 词:微孔膜 柠檬酸 中空纤维 二氧化硫 吸收 动力接触角 

分 类 号:TQ028.8[化学工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象