液阻软启动装置在水泵机组高压电动机的应用  被引量:1

The Application of Fluid Resistance Soft Starter in High Voltage Motor for Water Pump Unit

在线阅读下载全文

作  者:杨鸿儒[1] 王钊[1] 王新梅[2] 

机构地区:[1]独山子石化公司炼油厂,新疆独山子833600 [2]克拉玛依职业技术学院,新疆克拉玛依834000

出  处:《石油矿场机械》2007年第7期93-96,共4页Oil Field Equipment

摘  要:对GZYQ-YS型高压电动机液态变阻软启动装置的系统构成、工作原理及性能特点进行了分析。通过将水泵机组YK1250-2/999型高压电动机由直接启动改造为液态变阻软启动后的调试和运行,实现了电动机的恒流软启动,并将启动电流由原来的1000A左右降低到350A,改善了水泵机组电机的启动性能,减少了对电网的电压扰动,有效控制了连续启动性能的稳定性。The paper presents the system construction, the analysis of the work principle and the performance of GZYQ-YS high voltage motor for fluid resistance soft starter. Changing direct starting to fluid resistance starting for YK1250-2/999 high voltage motor and the summarizing its operation, we realized constant current starting thus its starting current was reduced from 1000 A to 350 A. As a result, the motor starting performance was improved so as to decrease pulsation in network and the stability of continuous starting was controlled effectively.

关 键 词:高压电动机 软启动 液态变阻 应用 

分 类 号:TE9[石油与天然气工程—石油机械设备]

 