检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]广州市番禺区疾病预防控制中心,广州511400 [2]广东工业大学轻工化工学院,广州510006
出 处:《中国卫生检验杂志》2007年第7期1225-1226,共2页Chinese Journal of Health Laboratory Technology
基 金:广州市番禺区科技计划资助项目(2005-Z17-1)
摘 要:目的:对氢化物发生-原子荧光光谱法测定铅的酸度介质条件进行分析和研究,选择出最适宜的盐酸介质条件。方法:通过在不同的盐酸介质条件下对铅的标样进行测定。结果:酸度对铅测定的荧光强度有非常大的影响,在合适的酸度范围下进行铅的测定,能获得较高的灵敏度和精密度。结论:以2.0%盐酸作载流,在1.6%~2.5%的较宽的盐酸浓度范围内,测定铅能提高荧光强度,且获得5%以内的相对标准偏差。Objective:The optimal acidity condition on determination of lead by hydride generation atomic fluorescence spectrometry was given by studying the different acidity condition of hydrochloric acid. Methods:Test sample of lead in different acidity condition of hydrochloric acid. Results: It was found that the acidity has great impact to the fluorescence intensity on determina- tion of lead. Within the appropriate acidity scope it comes with a higher accuracy and sensitivity result. Conclusion:Within the wider hydrochloric acid concentration scope of 1. 6% to 2. 5% , the fluorescence intensity on determination of lead by hydride generation atomic fluorescence spectrometry can be raised and acquire 5% of opposite and standard deviation with carrier of 2. 0% hydrochloric acid.