微型柱现场预富集流动注射火焰原子吸收光谱法测定环境水样中钴  被引量:5

Determination of Cobalt(Ⅱ) in Environmental Water by Micro-Column in-Situ Preconcentration and Flow Injection Flame Atomic Absorption Spectrometry

在线阅读下载全文

作  者:吴冬梅[1] 王爱霞[2] 

机构地区:[1]中国矿业大学煤矿瓦斯治理国家工程研究中心,徐州221008 [2]东北师范大学分析测试中心,长春130024

出  处:《理化检验(化学分册)》2007年第7期552-554,557,共4页Physical Testing and Chemical Analysis(Part B:Chemical Analysis)

基  金:国家自然科学基金(50473032)资助项目

摘  要:以负载8-羟基喹啉(Oxine)、二乙基二硫代氨基甲酸钠(DDTC)和吡咯啶二硫代氨基甲酸铵(APDC)三种螯合剂的活性炭为微型柱的吸附材料,采用微型柱现场采样分析技术实现了连续现场富集环境水样中痕量钴,并在实验室中采用在线解吸流动注射火焰原子吸收光谱法对吸附柱中富集的钴进行了测定。该方法用于环境水样中钴的测定,10 mL富集水样的检出限(3σ)为1.13μg.L-1,分析了3件水样中的钴,测定结果的RSD(n=6)值均小于1%。Trace amount of cobalt (Ⅱ) in environmental water sample was preconcentrated in situ by adsorption on a micro-column packed with activated carbon which has been loaded with oxine, DDTC and APDC. By using the on-the-spot sampling with the micro-column, traces of cobalt( Ⅱ ) in environmental water were enriched continuously. An on-line desorption and FI-FAAS analytical system was proposed for the determination of Cobalt ( Ⅱ ). Cobalt( Ⅱ ) on the micro-column was desorbed with 3 mol · L^-1 HNO3 and determined by FAAS. Detection limit (3a) of the method was found to be 1.13 μg · L^-1 , in 10 mL of the eluate as sample. In the analysis of 3 water samples by the proposed method, values of RSD's (n=6) obtained were less than 1%.

关 键 词:微型柱现场采样 在线解吸流动注射-火焰原子吸收光谱法 活性炭 8-羟基喹啉 二乙基二硫代氨基甲酸钠 吡咯啶二硫代氨基甲酸铵  环境水样 