蓄热式加热炉炉筋管绝热包扎结构改进  

Improvement of Adiabatic Enswathement Structure of Regenerative Heating Furnace Steam-cooling Water Pipe

在线阅读下载全文

作  者:马培旭[1] 韩晰宇[1] 

机构地区:[1]济南钢铁股份有限公司,山东济南250101

出  处:《山东冶金》2007年第3期51-52,共2页Shandong Metallurgy

摘  要:针对蓄热式加热炉汽化冷却热损失高的问题,分析认为,主要原因是原炉筋管绝热采用吊挂包扎块包扎方式,包扎不严密,结构不合理。改进采用整体浇注复合绝热包扎技术,包扎层抗剥落性能好,使用寿命长,改进后加热炉产汽量由10.52t/h降为6.8t/h,降低了成本,改善了钢坯加热质量。Aiming at the problem that heat energy of regenerative heating furnace steam-cooling was lost much more, analysis considered that the primary reason was the imprecise and inconsequential enswathement manner of suspending bricks for adiabatic of the stearn-cooling water pipe. Improving was adopting technology of whole moulding and compound adiabatic enswathement. It has better capability of resisting from coming off and long service life. After improvement, the quantity of steam was decreased from 10.52 t/h to 6.8 t/h, the cost is reduced and heating quality of billets is improved.

关 键 词:加热炉 绝热包扎 包扎块 整体浇注 改进 

分 类 号:TG307[金属学及工艺—金属压力加工]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象