Determination of Nickel and Palladium in Environmental Samples by Low Temperature ETV-ICP-OES Coupled with Liquid-liquid Extraction with Dimethylglyoxime as Both Extractant and Chemical Modifier  被引量:5

Determination of Nickel and Palladium in Environmental Samples by Low Temperature ETV-ICP-OES Coupled with Liquid-liquid Extraction with Dimethylglyoxime as Both Extractant and Chemical Modifier

在线阅读下载全文

作  者:PAN Liang QIN Yong-chao HU Bin JIANG Zu-cheng 

机构地区:[1]College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, P. R. China

出  处:《Chemical Research in Chinese Universities》2007年第4期399-403,共5页高等学校化学研究(英文版)

基  金:Supported by the National Natural Science Foundation of China(No.20575048).

摘  要:A novel method for the determination of nickel and palladium in environmental samples by low temperature ETV-ICP-OES with dimethylglyoxime(DMG) as both the extractant and chemical modifier has been developed. In this study, it was found that nickel and palladium can form complexes with dimethylglyoxime(0. 05%, mass fraction) at pH 6.0 and can be extracted into chloroform quantitatively. The complexes can be evaporated into plasma at a suita-ble temperature( 1400℃) for ICP-OES detection. Under the optimized conditions, the detection limits of nickel and palladium are 0.48 and 0. 40 ng/mL, respectively, while the RSD values are separately 5.0% and 3.1% (p = 50 ng/mL, n = 7). The proposed method was applied to the determination of the target analytes in environmental sam-ples with satisfactory results.A novel method for the determination of nickel and palladium in environmental samples by low temperature ETV-ICP-OES with dimethylglyoxime(DMG) as both the extractant and chemical modifier has been developed. In this study, it was found that nickel and palladium can form complexes with dimethylglyoxime(0. 05%, mass fraction) at pH 6.0 and can be extracted into chloroform quantitatively. The complexes can be evaporated into plasma at a suita-ble temperature( 1400℃) for ICP-OES detection. Under the optimized conditions, the detection limits of nickel and palladium are 0.48 and 0. 40 ng/mL, respectively, while the RSD values are separately 5.0% and 3.1% (p = 50 ng/mL, n = 7). The proposed method was applied to the determination of the target analytes in environmental sam-ples with satisfactory results.

关 键 词:Low temperature electrothermal vaporization ICP-OES DIMETHYLGLYOXIME Chemical modifier Nickel and palladium 

分 类 号:O614.813[理学—无机化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象