适用于研究低能裂变碎片电荷分布的探测器装置  被引量:1

Equipment to Measure Charge Distributions of Fragments in Low Energy Fission

在线阅读下载全文

作  者:王涛峰[1] 孟庆华[1] 王黎明[1] 朱丽萍[1] 韩洪银[1] 夏海鸿[1] 

机构地区:[1]中国原子能科学研究院核物理研究所,北京102413

出  处:《原子能科学技术》2007年第4期484-488,共5页Atomic Energy Science and Technology

摘  要:为研究252Cf自发裂变碎片电荷分布,建立了由屏栅电离室和ΔE-E粒子望远镜构成的探测器系统。在该系统中,将薄的屏栅电离室作为碎片的ΔE探测器,E探测器是金硅面垒半导体探测器。通过分析实验测量的4参数关联数据,得到了252Cf自发裂变碎片质量数、动能及碎片在气体ΔE探测器中的能量沉积分布等物理量。用多高斯(multi-Gaussian)分布函数对ΔE探测器的能量响应函数进行最小二乘法拟合,得到了在固定质量数AL*和动能条件下轻碎片的电荷分布。结果表明:该探测器系统的电荷分辨能力Z/ΔZ约为40∶1;建立起来的测量技术可用于测定235U(n,f)和239Pu(n,f)反应碎片的电荷分布。In order to study charge distributions of fragments in spontaneous fission of ^252Cf, a detector system, including a typical grid-ionization chamber and a △E-E particle telescope in which a thin grid-ionization chamber is served as the △E-section and the Esection is a surface barrier detector, was built up. From the measured four-parameter correlation data, the physical quantities, such as mass number, kinetic energy of fragments and energy deposited by fragments in the gas △E detector can be derived. The charge distributions at the fixed mass number AL and total kinetic energy (TKE) of the light fragments were obtained by the least-squares fiting of the response functions of △E detector with multi-Gaussian distributions representing all charge states. The results show that the charge resolution of Z/△Z≈40 : 1 can be given by this detector system. The measured technique in this work can be used to determine the charge distributions of fragments for other low energy fission reactions such as ^235SU(n, f) and ^239Pu(n, f).

关 键 词:屏栅电离室 ΔE-E粒子望远镜 碎片电荷分布 

分 类 号:TL817.7[核科学技术—核技术及应用]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象