某典型商用建筑空调系统能耗分析  被引量:4

Analysis of Air-conditioning System Energy Consumption in a Typical Commercial Building

在线阅读下载全文

作  者:罗清海[1] 陈国杰[1] 解晓蕾[1] 

机构地区:[1]南华大学城市建设学院,湖南衡阳421001

出  处:《制冷空调与电力机械》2007年第4期23-26,57,共5页Refrigeration Air Conditioning & Electric Power Machinery

摘  要:以某典型商用建筑为调查对象,对其空调系统的运行能耗进行了不同季节的逐时测定,对系统能耗结构、负荷指标、能效比、水系统输送系数等方面进行了分析研究,提出了系统节能改造的建议,包括:合并南北空调系统、增设水泵变速控制、调整新风运行方案、加强运行和维护管理等。The air-conditioning system energy consumption in a typical commercial building were analyzed in four aspects: the component of energy consumption,cooling load per square meter,coefficient of performance and coefficient of water distribution. Suggestions on improving the air-conditioning system are proposed as follows: 1 )combining the south and north subsystem into a unit system; 2)adding variable speed control for water pump; 3) modifying the running scheme for fresh air handling units; 4) intensifying the management and maintenance of the system.

关 键 词:商用建筑 空调能耗 节能 

分 类 号:TU831.3[建筑科学—供热、供燃气、通风及空调工程]

 