检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
出 处:《制冷空调与电力机械》2007年第4期23-26,57,共5页Refrigeration Air Conditioning & Electric Power Machinery
摘 要:以某典型商用建筑为调查对象,对其空调系统的运行能耗进行了不同季节的逐时测定,对系统能耗结构、负荷指标、能效比、水系统输送系数等方面进行了分析研究,提出了系统节能改造的建议,包括:合并南北空调系统、增设水泵变速控制、调整新风运行方案、加强运行和维护管理等。The air-conditioning system energy consumption in a typical commercial building were analyzed in four aspects: the component of energy consumption,cooling load per square meter,coefficient of performance and coefficient of water distribution. Suggestions on improving the air-conditioning system are proposed as follows: 1 )combining the south and north subsystem into a unit system; 2)adding variable speed control for water pump; 3) modifying the running scheme for fresh air handling units; 4) intensifying the management and maintenance of the system.
分 类 号:TU831.3[建筑科学—供热、供燃气、通风及空调工程]
正在载入数据...