闽、浙两省变电所外空间工频电磁污染分布研究  被引量:1

Study on the power frequency electromagnetic field pollution distribution of the transformer substation surroundings in Fujian and Zhejiang provinces

在线阅读下载全文

作  者:仇丰[1] 焦景慧[2] 施丽莉[3] 

机构地区:[1]华东勘测设计研究院环境保护与工程移民设计院,浙江杭州310014 [2]福建省电力有限公司,福建福州350003 [3]杭州市环境监测中心站,浙江杭州310007

出  处:《电力环境保护》2007年第4期28-30,共3页Electric Power Environmental Protection

摘  要:以闽、浙两省110 kV以上等级变电所的电磁场监测结果为基础,着重研究了各电压等级变电所边界处及边界外的空间工频电磁场场强分布规律,分析和探讨了变电所外空间电磁污染的现状,为进一步开展变电所的电磁环境影响研究提出了建设性意见。Based on the measured results of electromagnetic field of the transformer substations above 110kV level in Fujian and Zhejiang provinces,the space distribution rule of power frequency electromagnetic fields on and out of the boundary of various voltage level transformer substations are researched. The status in quo of electromagnetic pollution of transformer substations surroundings are analyzed emphatically, Some constructive suggestions for further research of electromagnetic environment of transformer substations are put forward.

关 键 词:变电所 工频电磁场 电磁污染 

分 类 号:X591[环境科学与工程—环境工程]

 