检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:水振宇[1] 花威[1] 赵红光[1] 文万信[1]
机构地区:[1]苏州大学放射医学与公共卫生学院,江苏苏州215123
出 处:《核化学与放射化学》2007年第3期189-192,共4页Journal of Nuclear and Radiochemistry
基 金:江苏省高校省级重点实验室开放课题资助项目(KJS05026)
摘 要:采用尿氚不脱色猝灭校正法对10人尿样在加氚制样后直接进行液闪测量,同时与常规蒸馏脱色法进行比较。结果表明,当α=0.05时,2种方法的测量结果没有明显差异。但不脱色猝灭校正法在操作上仅需时4min,适于短时间内大规模尿氚检测,可作为核设施工作人员尿氚常规监测的主要方法。The urine samples from ten persons added with tritium were prepared with color- quenching calibration and measured by liquid scintillation counting. This method was compared with that of distillation decoloration. Results obtained at the significance level of 0.05 show that there is no significant difference between two methods. The color-quenching calibration only needs about 4 min in pretreating per sample, and that fits massive urine tritium monitoring in brief time. Therefore, color-quenching calibration could be used as the main method to routine monitoring of tritium in urine samples of the workers in nuclear facilities.