双水内冷发电机转子出水支座甩水现象分析及处理措施  被引量:1

ANALYSIS OF WATER THROW-OFF PHENOMENON FROM WATER-DISCHARGING SUPPORT OF THE ROTOR IN DUAL INTERNAL WATER COOLING GENERATOR AND REMEDIAL MEASURES THEREOF

在线阅读下载全文

作  者:周德元[1] 

机构地区:[1]华夏电力公司,福建厦门361026

出  处:《热力发电》2007年第5期35-37,共3页Thermal Power Generation

摘  要:从发电机转子水冷系统设计、安装和运行维护入手,详细分析了嵩屿电厂二期300 MW双水内冷发电机转子出水支座甩水原因,认为主要由于出水支座内水位太高和风压过大、转子卸水槽错位造成。对此,提出了改进方案,实施后彻底消除了甩水现象。starting with the system design, equipment installation, and maintenance in operation of the water cooling rotor in generator, the causes leading to water throw- off from water - discharging susupport of the rotor in dual internal water cooling 300 MW generator in secondary - phase project of Songyu Power Plant have been analysed in detail. After suggesting and implementing the improvement scheme, the water throw- off phenomenon has been thoroughly eliminated.

关 键 词:汽轮发电机 双水内冷 转子水冷系统 出水支座 甩水 

分 类 号:TM311[电气工程—电机]

 