心肌显像剂^(99)Tc^mN-NOET在健康人体中的安全性、生物学分布及内照射辐射吸收剂量  被引量:1

Safety,Biodistribution,and Dosimetry of Myocardial Imaging Agent ^(99)Tc^mN-NOET in Healthy Volunteers

在线阅读下载全文

作  者:杜延荣[1] 李方[1] 王学斌[2] 唐志刚[2] 田建[1] 巴建涛[1] 龙明清[1] 张俊波[2] 

机构地区:[1]中国医学科学院北京协和医学院北京协和医院核医学科,北京100730 [2]北京师范大学化学学院,北京100875

出  处:《中国医学科学院学报》2007年第4期517-521,共5页Acta Academiae Medicinae Sinicae

摘  要:目的研究心肌显像剂99TcmN-NOET在健康人体中的安全性、生物学分布及内照射辐射吸收剂量。方法10名正常志愿者静脉注射99TcmN-NOET744~792MBq后,观察受试者24h内的生命体征变化及有无不良反应,于给药后1、30min,1、2、4、8和24h进行全身显像以测定生物分布,用感兴趣区技术对重要器官进行放射性计数,用MIR-DOSE3.0剂量估算软件,估算各主要受照器官的内照射辐射吸收剂量。于给药后1和4h进行心肌断层显像。结果试验后24h内受试者的生命体征如心率、血压和心电图无明显变化,无任何不良反应。所有受试者的血清学和生化指标均无改变。心肌对99TcmN-NOET的摄取较高,2h时达2.68%;给药后30min心/肺比值大于1,2h达最大,为1.91±0.53。有效剂量当量为1.28×10-5Sv/MBq,按一次给药740MBq计算,各主要器官的内照射辐射吸收剂量均低于50mGy。结论心肌对99TcmN-NOET的摄取率高,断层图像清晰,99TcmN-NOET的内照射辐射吸收剂量低,安全性好,符合临床用放射性显像剂的要求。Objective To study the safety, biodistribution, and dosimetry of myocardial perfusion imaging agent ^(99)Tc^mN-NOET in 10 healthy volunteers. Methods 744-792 MBq of ^(99)Tc^mN-NOET was injected to each volunteer. Safety parameters and adverse event was measured in 24 hours of injection. Biodistribution was studied by whole-body imaging 1, 30 minutes, 1, 2, 4, 8, and 24 hours after the injection of ^(99)Tc^mN-NOET. The estimation of dosimetry was based on the standard medical internal radiation dose method using MIRDOSE 3.0 analysis program. Myocardial single photon emission computed tomography (SPECT) imaging was performed at 1 and 4 hours after injection. Results No undesirable effects were reported by the subject during 24 hours after injection of ^(99)Tc^mN-NOET . No clinically significant changes were found in vital signs (heart rate, blood pressure, and electrocardiogram). No biochemical aspects and serology changes were measured. The myocardial SPECT imaging was clear. Cardiac uptake of ^(99)Tc^mN-NOET was as high as 2.68% at 2 hours after injection. The heart to lung ratio was more than 1 from 30 minutes after injection, reaching a maxi- mum of 1.91 ± 0.53 at 2 hours after injection. Radiation dosimetry calculations indicated an effective absorbed dose of 1.28 ×10^-5 Sv/MBq. The dosimetry in each main organ is lower then 50mGy given 740 MBq of ^(99)Tc^mN-NOET in once imaging. Conclusions effective absorbed dose. It's a safe myocardial ^(99)Tc^mN-NOET exhibits high cardiac uptake and low estimated perfusion imaging agent.

关 键 词:99TcmN-NOET 心肌灌注显像 生物分布 吸收剂量 

分 类 号:R969[医药卫生—药理学] R965.3[医药卫生—药学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象