检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]山东建筑大学市政与环境工程学院,山东济南250101 [2]济南市市政工程设计研究院有限责任公司,山东济南250002
出 处:《水处理技术》2007年第9期75-77,共3页Technology of Water Treatment
基 金:山东省自然科学基金项目(Y2002F25)
摘 要:在设定的絮凝条件下,以济南市水质净化一厂初沉池进水为试验水样,无机高分子絮凝剂聚合氯化铁铝(PFAC)和有机高分子絮凝剂聚丙烯酰胺(PAM)为试验药剂,浊度、COD、溶解氧等为测定指标,进行了一系列气动絮凝试验。试验结果表明,采用气动絮凝方式强化城市污水一级处理效果明显。单独投加25mg/LPFAC时,浊度、COD去除率分别为90%、78.5%,溶解氧增加230%;组合投加20mg/LPFAC+1.0mg/LPAM时,浊度、COD去除率分别为92.4%、78.6%,溶解氧增加246%。Under the condition of set coagulation, a aerated flocculation test was conducted with the influent of the primary sediment pool of a water purifying plants as the water sample, inorganic polymer flocculent PFAC and organic polymer floceulent PAM as test chemicals, and turbidity,COD,DO as determining indexes. It was showed that enhancing primary municipal sewage treatment by aerated flocculation had obvious effect; when being single dosage of 25mg/L PFAC, the turbidity and COD removal rate reached to 90% and 78.5% respectively,DO content was increased by 230%;when being combining dosage of 20mg/L PFAC+1.0 mg/L PAM,turbidity and COD removal rate reached to 92.4% and 78.6% respectively,DO content was increased by 246%.
分 类 号:X703.1[环境科学与工程—环境工程]