Microwave digestion polarography for determining seven trace elements in Salvia Miltiorrhiza Root and compound Salvia Miltiorrhiza Root injection simultaneously  被引量:1

Microwave digestion polarography for determining seven trace elements in Salvia Miltiorrhiza Root and compound Salvia Miltiorrhiza Root injection simultaneously

在线阅读下载全文

作  者:黄熠 张泰铭 曹娟 梁逸曾 

机构地区:[1]School of Chemistry and Chemical Engineering, Central South University

出  处:《Journal of Central South University of Technology》2007年第4期514-519,共6页中南工业大学学报(英文版)

基  金:Proejcr(20235020) supported by the National Natural Science Foundation of China

摘  要:The sensitive second derivative waves of Cu(Ⅱ),Pb(Ⅱ),Cd(Ⅱ),Ni(Ⅱ),Zn(Ⅱ),Fe(Ⅱ)and Mn(Ⅱ),forming in the substrate solution(pH=9.26)consisting of ammonia,ammonium chlorid,gelatin and ascorbic acid were researched.The peak potentials of the polarographic waves of the seven ions are at about 0.48,0.63,0.79,1.04,1.28,1.44 and 1.60 V respectively.Combining with microwave technique,a new method for the simultaneous determination of the seven trace elements in Chinese traditional medicine was developed.The method is easy to operate,rapid,simple and convenient.When the signal-to-noise rate equals 3,the detection limits of Cu,Pb,Cd,Ni,Zn,Fe and Mn are 4.2×10 3,5.3×10 3,2.1×10 3,5.8×10 4,3.0×10 3,7.7×10 4 and 1.1×10 3 μg/mL respectively.Well linear relationships exist between the concentrations and the peak currents when Cu,Pb,Cd,Ni,Zn,Fe and Mn concentrations are within 8.5×10 3 10,9.7×10 3 10,4.5×10 3 10,1.2×10 3 10,6.4×10 3 10,1.5×10 3 10 and 2.8×10 3 10 μg/mL,respectively.The method has been used to the simultaneous determination of the seven trace elements in Salvia Miltiorrhiza Root and compound Salvia Miltiorrhiza Root injection,the relative standard deviations(RSDs)of the Cu,Pb,Cd,Ni,Zn,Fe and Mn in the two medicines are 3.9% and 5.8%,4.0% and 4.1%,4.3% and 5.7%,4.9% and 5.3%,4.4% and 4.7%,3.5% and 4.0%,0.51% and 2.8%,respectively;the comparisons of the determination results with the values obtained by the standard method indicate that the presented method has very well veracity.The sensitive second derivative waves of Cu(Ⅱ), Pb( Ⅱ ), Cd( Ⅱ ), Ni( Ⅱ ), Zn( Ⅱ ), Fe( Ⅱ ) and Mn(Ⅱ), forming in the substrate solution (pH-9.26) consisting of ammonia, ammonium chlorid, gelatin and ascorbic acid were researched. The peak potentials of the polarographic waves of the seven ions are at about -0.48, -0.63, -0.79, -1.04, -1.28, -1.44 and -1.60 V respectively. Combining with microwave technique, a new method for the simultaneous determination of the seven trace elements in Chinese traditional medicine was developed. The method is easy to operate, rapid, simple and convenient. When the signal-to-noise rate equals 3, the detection limits of Cu, Pb, Cd, Ni, Zn, Fe and Mn are 4.2× 10^-3, 5.3× 10^-3, 2.1× 10^-3, 5.8× 10^-4, 3.0× 10^-3, 7.7 × 10-4 and 1.1 × 10^-3 μg/mL respectively. Well linear relationships exist between the concentrations and the peak currents when Cu, Pb, Cd, Ni, Zn, Fe and Mn concentrations are within 8.5× 10^-3 10, 9.7× 10^-3-10, 4.5× 10^-3-10, 1.2× 10^-3-10, 6.4× 10^-3-10, 1.5 × 10^-3 10 and 2.8 × 10^-3-10 μg/mL, respectively. The method has been used to the simultaneous determination of the seven trace elements in Salvia Miltiorrhiza Root and compound Salvia Miltiorrhiza Root injection, the relative standard deviations(RSDs) of the Cu, Pb, Cd, Ni, Zn, Fe and Mn in the two medicines are 3.9% and 5.8%, 4.0% and 4.1%, 4.3% and 5.7%, 4.9% and 5.3%, 4.4% and 4.7%, 3.5% and 4.0%, 0.51% and 2.8%, respectively; the comparisons of the determination results with the values obtained by the standard method indicate that the presented method has very well veracity.

关 键 词:derivative polarographic wave microelement Salvia Miltiorrhiza Root compound Salvia Miltiorrhiza Root injection 

分 类 号:O657.14[理学—分析化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象