流式细胞术和SSP-PCR法检测HLA-B27抗原的比较  被引量:4

Comparison of results of detection of HLAB27 antigen by cytometry and SSPPCR

在线阅读下载全文

作  者:黄河[1] 孙燕燕[1] 眭维国[1] 陈洁晶[1] 蓝慧娟[1] 戴勇[1] 

机构地区:[1]中国人民解放军第181医院肾脏科,广西桂林541000

出  处:《中国热带医学》2007年第9期1662-1663,共2页China Tropical Medicine

摘  要:目的分析流式细胞术(FCM)用于强宜性脊柱炎(AS)患者人类白细胞抗原B27(HLA-B27)表达情况的测定效果,同时以药物特异性聚合酶链反应(SSP-PCR)进行对照。方法采用FCM法检测74例临床疑似AS患者的HLA-B27,将二者结果进行分析比对。结果两种检测方法检测,结果符合率为95.9%,经Kappa值评价有很强的一致性(K=0.95),无统计学意义(P>0.05)。结论FCM法是一种快捷、简便、高效的HLA-B27检测方法,适合于临床应用。Objective To evaluate the results of detection of HLA - B27 antigen in ankylosing spondylitis patients by flow eytometry (FCM) and compared with SSP - PCR. Methods A total of 74 samples from suspected ankylosing spondylitis were collected and the expression of HLAA - B27 was determined by FCM and SSP - PCR. Results The coincidence rate of the two methods was 95.9% without statistical significance (P 〉 0. 05 ). Conclusion FCM is a rapid and reliable method for determina6on of HLA - B27.

关 键 词:HLA—B27 强直性脊柱炎 流式细胞术 

分 类 号:R593.22[医药卫生—内科学]

 