出  处:《分析试验室》2007年第9期113-115,共3页Chinese Journal of Analysis Laboratory

摘  要:报道了采用ICP-AES法测定AuNiGd合金中Ni、Gd、Pd、Fe、Bi。对测定元素的波长、测定条件进行了选择;考察了基体和无机酸对测定的影响;在优化条件下,对试样进行测定,其相对标准偏差(n=15)Ni1、6%、Gd1.8%、Pd13%、Fe4.9%、Bi13%;回收率Ni98%~105%、Gd97%~99%、Pd101%~105%、Fe98%~104%、Bi104%~106%。The determination of Ni, Gd, Pd, Fe and Bi in AuNiGd alloy is reported in this article. Measurement conditions are chosen and the effect of matrix and inorganic acid on the determination is tested. The matched matrix method is applied in the determination. Under optimized conditions, three samples are determined. The RSDs (n = 15) of this method are Ni 1.6%, Gd 1.8%, Pd 13%, Fe 4.9% and Bi 13% and the recoveries are Ni 98%~ 105%, Gd 97%~ 99%, Pd 101% ~105%, Fe 98% ~ 104% and Bi 104% ~106%.