某型救生钟生命支持系统性能人体试验  被引量:1

Investigation of life support system of a type of rescue bell in human beings

在线阅读下载全文

作  者:顾靖华[1] 金凤来[2] 陈海庭[1] 彭勤健[2] 胡金凯 苏志渊[1] 

机构地区:[1]海军医学研究所 [2]海司航保部 [3]解放军92001部队861船

出  处:《海军医学杂志》2007年第3期198-200,共3页Journal of Navy Medicine

摘  要:目的:验证生命支持系统改换装后的总体性能。方法:救生钟在常压下进行10人8 h试验。结果:整个试验过程中,钟内CO2浓度始终未超过指标上限1.5%,钟内O2浓度基本保持稳定,均在21%左右。结论:生命支持系统改换装后,能满足技战指标要求,工作性能稳定。Objective: To verify the ensemble performance of the life support system after repackaging. Methods: An experiment of rescue bell had been carried out in ten men subjects for eight hours. Results: During experiment, the concentration of CO2 in the bell had not exceeded 1.5 % of top limit of index all along, and that of O2 in the bell had kept about 21%. Conelnsion: The ensemble performance of the life support system is stable and can provide a safe living condition.

关 键 词:生命支持系统 CO2吸收剂 性能 人体试验 

分 类 号:R841.4[医药卫生—航空、航天与航海医学]

 