作 者:陆颂芳[1] 包玉生[1] 王春仁[1] 彭屹[1] 于晓军[1] 孔桦[1] 许海燕[1] 杨子彬[1]
机构地区:[1]中国医学科学院中国协和医科大学基础医学研究所,北京100005
出 处:《中国医学科学院学报》1997年第2期140-144,共5页Acta Academiae Medicinae Sinicae
基 金:卫生部留学回国人员启动基金
摘 要:本研究对比了双腔和单腔主动脉内气囊反搏对肾脏血流动力学各参数的影响,发现双腔主动脉内气囊反搏未引起肾脏的血流动力学参数不良变化。对比肾动脉去神经前后主动脉内气囊反搏结果发现,反搏时产生的脉动会对血管神经系统产生刺激,从而降低肾血管局部的阻力。这是气囊反搏使肾脏血流量增加的最重要因素。The effects of the double chamber intra-aortic balloon (DIAB) and the single chamberintra-aortic balloon (SIAB) on the hemodynamic parameters in the kidney were studied. Nonegative effect of both cases was observed.Before and after removing the renal nerve system, the DIAB was used and the resultshad been compared. The pulse produced by pumping activized the renal nerve system and re-duced the renal vascular resistance.Therefore the reduction of the renal vascular resistance is an important reason for in-creasing the renal blood flow during intra-aortic balloon pumping.
关 键 词:主动脉内 气囊反搏 肾脏血流 血管阻力 神经活动
分 类 号:R334.1[医药卫生—人体生理学] R318.1[医药卫生—基础医学]