厌氧-好氧-过滤法处理树脂废水  被引量:1

Colophony Wastewater Treatment by Anaerobic-aerobic-filter Process

在线阅读下载全文

作  者:龙映臣 王诗发 杨英 

机构地区:[1]四会市环境保护监测站,广东四会526200 [2]广州市金龙峰环保设备工程有限公司,广东广州510000 [3]广州钢铁集团设计院,广东广州510380

出  处:《广东化工》2007年第10期89-91,72,共4页Guangdong Chemical Industry

摘  要:通过工程实例,介绍缺氧-好氧-过滤组合工艺处理树脂生产废水的效果及主要设计参数。运行结果表明:CODCr、BOD5及SS的去除率达99.9%,99.95%和98.57%,最终出水水质达到广东省地方标准《水污染物排放限值》(DB44/26-2001)第二时段一级标准。组合工艺处理树脂废水处理效果好,运行费用低,带来了显著的经济效益和环境效益。Through the project example, this paper introduced the effect and the main design parameters using in colophony wastewater treatment by anaerobic-aerobic-filter process. The operation results showed that CODcr, BOD5 and SS removal rate reached 99.9%, 99.95% and 98.57%. The quality of treated water achieved the Guangdong province local standard "Discharge limits of water pollutants" (DB44/26-2001) second time interval level standard. This craft had a good effect and low cost in colophony wastewater treatment. It also brought economy and environment benefit.

关 键 词:树脂废水 缺氧 好氧 过滤 