检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:林征宇[1] 江飞[1] 郑义浩[1] 朱璐珑[1] 陈德华[1]
机构地区:[1]福建医科大学附属第一医院影像科,福州350005
出 处:《放射学实践》2007年第10期1107-1109,共3页Radiologic Practice
摘 要:目的:介绍多层螺旋CT导向下经皮穿刺活检的技术方法,并评价其临床应用价值。方法:76例患者均在16层螺旋CT导向下进行经皮穿刺活检或治疗。肺部57例,纵隔5例,胸膜2例,骨骼肌肉系统4例,肝脏4例,肾脏、乳腺、甲状腺及胰腺各1例。结果:本组76例均穿刺成功。病理检出75例(75/76)。其中肺部恶性病变40例,良性病变16例。结论:多层CT引导下的经皮穿刺活检是一种安全、准确的新技术。Objective:To introduce MSCT-guided percutaneous biopsy technique and evaluate the clinic applying value. Methods:76 patients were performed percutaneous biopsy under the guidance of 16-slices MSCT, 57 cases of pulmonary lesions,5 cases of mediastinum,2 cases of pleura membrane,4 cases of skeletal musculature,4 cases of livers,a case of kidney, mammary gland thyroid and pancreas lesion were performed. Results: 76 punctures were completed successfully, 75 cases obtained pathological diagnosis (75/76). 16 were benign and 40 malignant pulmonary lesions were found. Conclusion: MSCT-guided percutaneous biopsy is a safe and accurate new technique.
关 键 词:体层摄影术 X线计算机 活组织检查 针吸 放射学 介入性