EXPERIMENTAL RESEARCH ON AERODYNAMIC PERFORMANCE AND EXIT FLOW FIELD OF LOW PRESSURE AXIAL FLOW FAN WITH CIRCUMFERENTIAL SKEWED BLADES  被引量:19

EXPERIMENTAL RESEARCH ON AERODYNAMIC PERFORMANCE AND EXIT FLOW FIELD OF LOW PRESSURE AXIAL FLOW FAN WITH CIRCUMFERENTIAL SKEWED BLADES

在线阅读下载全文

作  者:LI Yang OUYANG Hua DU Zhao-hui 

机构地区:[1]School of Mechanical Engineering, Shanghai Jiaotong University, Shanghai 200030, China

出  处:《Journal of Hydrodynamics》2007年第5期579-586,共8页水动力学研究与进展B辑(英文版)

基  金:supported by the National Natural Science Foundation of China (Grant No.50406017).

摘  要:In this article, the low pressure axial flow fan with circumferential skewed rotor blade, including the radial blade, the forward-skewed blade and the backward-skewed blade, was studied with experimental methods. The aerodynamic performance of the rotors was measured. At the design condition at outlet of the rotors, detailed flow measurements were performed with a five-hole probe and a Hot-Wire Anemometer (HWA). The results show that compared to the radial rotor, the forward-skewed rotor demonstrates a wider Stable Operating Range (SOR), is able to reduce the total pressure loss in the hub region and make main loading of blade accumulating in the mid-span region. There is a wider wake in the upper mid-span region of the forward-skewed rotor. Compared to the radial rotor, in the backward-skewed rotor there is higher total pressure loss near the hub and shroud regions and lower loss in the mid-span region. In addition, the velocity deficit in the wake is lower at mid-span of the backward-skewed rotor than the forward-skewed rotor.In this article, the low pressure axial flow fan with circumferential skewed rotor blade, including the radial blade, the forward-skewed blade and the backward-skewed blade, was studied with experimental methods. The aerodynamic performance of the rotors was measured. At the design condition at outlet of the rotors, detailed flow measurements were performed with a five-hole probe and a Hot-Wire Anemometer (HWA). The results show that compared to the radial rotor, the forward-skewed rotor demonstrates a wider Stable Operating Range (SOR), is able to reduce the total pressure loss in the hub region and make main loading of blade accumulating in the mid-span region. There is a wider wake in the upper mid-span region of the forward-skewed rotor. Compared to the radial rotor, in the backward-skewed rotor there is higher total pressure loss near the hub and shroud regions and lower loss in the mid-span region. In addition, the velocity deficit in the wake is lower at mid-span of the backward-skewed rotor than the forward-skewed rotor.

关 键 词:low pressure axial flow fan circumferential skewed blade aerodynamic performance exit flow field StableOperating Range (SOR) 

分 类 号:TV13[水利工程—水力学及河流动力学]

 