COUPLING EFFECT BETWEEN RELIABILITY OF BEDDING LAYER AND STABILITY OF DOWNSTREAM CONCRETE SLAB OF OVERFLOW EARTH-ROCK COFFERDAM  被引量:4

COUPLING EFFECT BETWEEN RELIABILITY OF BEDDING LAYER AND STABILITY OF DOWNSTREAM CONCRETE SLAB OF OVERFLOW EARTH-ROCK COFFERDAM

在线阅读下载全文

作  者:HU Zhi-gen FAN Xi-e HUAI Wen-xin LIU Quan ZHU Ming-xing 

机构地区:[1]State Key Laboratory of Water Resource and Hydropower Engineering Science, Wuhan University, Wuhan 430072, China [2]China Gezhouba (Group) Corporation, Yichang 443002, China

出  处:《Journal of Hydrodynamics》2007年第5期613-622,共10页水动力学研究与进展B辑(英文版)

基  金:supported by the National Natural Science Foundation of China (Grant No. 50579056);the Joint Fund of Yalong River Hydropower Development Research;the National Natural Science Foundation of China(Grant No. 50539120)

摘  要:The protection of downstream concrete slab is a key issue for the stability of overflow earth-rock cofferdam. The coupling effect between bedding layer and concrete slab was taken into account when the stability of downstream concrete slab was researched. The characteristics of overflow and seepage over the downstream concrete slab were investigated when floodwater passes over the cofferdam. Firstly a limit equation of seepage failure for the bedding layer was derived with the consideration of geometric and mechanical factors, and a reliability model was established and numerically simulated. Then based on the reliability calculation for the bedding layer, the coupling effect between bedding layer and downstream concrete slab was analyzed. Under the most unfavorable pressure condition for the concrete slab, its instability criterion was put forward, which offers a structural design tool of downstream concrete slab for overflow earth-rock cofferdam. Compared with model tests, it shows that the model of reliability calculation of bedding layer and the stability analysis of downstream concrete slab are effective.The protection of downstream concrete slab is a key issue for the stability of overflow earth-rock cofferdam. The coupling effect between bedding layer and concrete slab was taken into account when the stability of downstream concrete slab was researched. The characteristics of overflow and seepage over the downstream concrete slab were investigated when floodwater passes over the cofferdam. Firstly a limit equation of seepage failure for the bedding layer was derived with the consideration of geometric and mechanical factors, and a reliability model was established and numerically simulated. Then based on the reliability calculation for the bedding layer, the coupling effect between bedding layer and downstream concrete slab was analyzed. Under the most unfavorable pressure condition for the concrete slab, its instability criterion was put forward, which offers a structural design tool of downstream concrete slab for overflow earth-rock cofferdam. Compared with model tests, it shows that the model of reliability calculation of bedding layer and the stability analysis of downstream concrete slab are effective.

关 键 词:overflow earth-rock cofferdam couplingeffect reliability calculation stability analysis Monte Carlomethod 

分 类 号:TV139.1[水利工程—水力学及河流动力学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象