奥扎格雷钠口服溶液人体尿药浓度研究  被引量:1

Study on Ozagrel in Human Urine

在线阅读下载全文

作  者:王珍[1] 金锐[1] 孙考祥[2] 杜智敏[1] 

机构地区:[1]哈尔滨医科大学附属第二医院临床药学药物研究所,哈尔滨150086 [2]烟台大学,山东烟台264005

出  处:《中国药学杂志》2007年第20期1567-1569,共3页Chinese Pharmaceutical Journal

摘  要:目的建立测定人尿中奥扎格雷钠浓度的HPLC方法;通过测定12名健康受试者单次po200mg奥扎格雷钠口服溶液后体内的尿药浓度,考察奥扎格雷钠体内代谢过程。方法采用Diamonsil C18柱(4.6mm×150mm,5μm),磷酸盐缓冲液(pH=3.0)-乙腈(94:6)为流动相,流速为1.5mL.min-1,咖啡因为内标,紫外检测波长为276nm。结果奥扎格雷钠在0.01~10mg.L-1内线性关系良好,r=0.9962;健康受试者服药后12h内有(41.77±15.47)%的奥扎格雷钠从尿中排出。结论此方法灵敏、准确、稳定,可用于奥扎格雷钠体内代谢研究;奥扎格雷钠主要以原型从尿中排出。OBJECTIVE To establish a HPLC assay for determining ozagrel in urine and to investigate the metabolism of ozagrel in human urine. METHODS The separation was performed on a Diamonsil C18 column (4. 6 mm ×150 mm, 5 μm). The mobile phase consisted of phosphate buffer( pH = 3.0)-acetonitrile(94: 6)with a flow rate of 1.5 mL·min^-1. Caffein was used as the interal standard,the detection wavelength was at 276 nm. RESULTS The good linearity was obtained over the range of 0. 01 - 10 mg·L^-1 with good correlation coefficient ( r = 0. 996 2). (41.77 ±15.47) % ozagrel was eliminated from body in 12 h. CONCLUSION The method was sensitive, accurate and stable. Ozagre was eliminated in urine from body as drug prototype.

关 键 词:奥扎格雷钠 高效液相色谱法 尿药浓度 

分 类 号:R969[医药卫生—药理学]

 