Comparison of membrane fouling during short-term filtration of aerobic granular sludge and activated sludge  被引量:18

Comparison of membrane fouling during short-term filtration of aerobic granular sludge and activated sludge

在线阅读下载全文

作  者:ZHOU Jun YANG Feng-lin MENG Fan-gang AN Peng WANG Di 

机构地区:[1]School of Environmental and Biological Science and Technology, Dalian University of Technology, Dalian 116024, China

出  处:《Journal of Environmental Sciences》2007年第11期1281-1286,共6页环境科学学报(英文版)

基  金:Project supported by the University Doctorial Research Foundation.Ministry of Education of China(No.20030141022).

摘  要:Aerobic granular sludge was cultivated adopting internal-circulate sequencing batch airlift reactor. The contradistinctive experiment about short-term membrane fouling between aerobic granular sludge system and activated sludge system were investigated. The membrane foulants was also characterized by Fourier transform infrared (FTIR) spectroscopy technique. The results showed that the aerobic granular sludge had excellent denitrification ability; the removal efficiency of TN could reach 90%. The aerobic granular sludge could alleviate membrane fouling effectively. The steady membrane flux of aerobic granular sludge was twice as much as that of activated sludge system. In addition, it was found that the aerobic granular sludge could result in severe membrane pore-blocking, however, the activated sludge could cause severe cake fouling. The major components of the foulants were identified as comprising of proteins and polysaccharide materials.Aerobic granular sludge was cultivated adopting internal-circulate sequencing batch airlift reactor. The contradistinctive experiment about short-term membrane fouling between aerobic granular sludge system and activated sludge system were investigated. The membrane foulants was also characterized by Fourier transform infrared (FTIR) spectroscopy technique. The results showed that the aerobic granular sludge had excellent denitrification ability; the removal efficiency of TN could reach 90%. The aerobic granular sludge could alleviate membrane fouling effectively. The steady membrane flux of aerobic granular sludge was twice as much as that of activated sludge system. In addition, it was found that the aerobic granular sludge could result in severe membrane pore-blocking, however, the activated sludge could cause severe cake fouling. The major components of the foulants were identified as comprising of proteins and polysaccharide materials.

关 键 词:membrane bioreactor membrane fouling pore-blocking cake layer resistance aerobic granular sludge 

分 类 号:X705[环境科学与工程—环境工程]

 