组合式空气热湿处理系统设计  被引量:2

Design of combined air handling system for heat-moisture treatment

在线阅读下载全文

作  者:蒋华[1] 靳晓栋 杨林生[3] 柳玉林[1] 何明顺[1] 

机构地区:[1]华中科技大学 [2]河南南阳回龙抽水蓄能发电分公司 [3]山东泰山抽水蓄能电站有限责任公司

出  处:《制冷与空调》2007年第5期33-37,46,共6页Refrigeration and Air-Conditioning

摘  要:提出一种组合式空气处理系统,在结构上采用复叠形式。该系统能够按照不同运行模式实现对空气的降温、除湿、加热和加湿处理。对两级冷冻除湿过程进行分析,并对系统流程和结构进行改进。与传统空气处理方式相比,组合式空气处理系统一方面避免分别购置空气处理设备,另一方面扩大系统工作的环境温度范围和空气的热湿处理范围。Presents a kind of combined air treating system, adopts cascade style configuration. This system can implement cooling, dehumidification, heating and humidification according to different operation modes. Analyzes the two-stage refrigeration dehumidification, also improves the system's flow and configuration. Compared with the traditional air handling system,this system can decrease investment of equipment, also can extend the scope of environment temperature under which the system works and of temperature and humidity which the system can dispose.

关 键 词:湿度 高温热泵 冷冻除湿 复叠循环 

分 类 号:TU83[建筑科学—供热、供燃气、通风及空调工程]

 