检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王怡宁[1] 金征宇[1] 孔令燕[1] 张竹花[1] 宋兰[1] 牟文斌[1] 王沄[1] 赵文敏[1]
机构地区:[1]中国医学科学院中国协和医科大学北京协和医院放射科,北京100730
出 处:《中国医学影像技术》2007年第10期1503-1506,共4页Chinese Journal of Medical Imaging Technology
摘 要:目的比较双源CT与64层螺旋CT冠状动脉成像的图像质量。方法对100例临床可疑冠心病患者[计为A组,男54例,年龄(57.9±11.3)岁]进行双源CT心电门控增强扫描,对另外100例临床可疑冠心病患者[计为B组,男59例,年龄(58.0±11.1)岁]进行64层螺旋CT心电门控增强扫描。B组患者检查前用β受体阻滞剂控制心率。对两组图像进行质量评分、冠状动脉节段显示率和最佳重建时相分析。结果A组的心率显著高于B组,分别是(71±12)次/min,(61±6)次/min,P〈0.05,两组的图像质量评分差异无显著性,分别是1.31±0.53和1.25±0.50,P〉0.05。A、B组可评价的冠状动脉节段显示率分别是98.9%和99.1%,P〉0.05。平均心率〈70次/min的患者,绝大多数最佳重建时相在50%-80%R-R间期范围内;平均心率≥70次/min的患者,绝大多数最佳重建时相在30%-80%R-R间期范围内。结论与64层螺旋CT相比,时间分辨力的提高使双源CT能够在相当宽的心率范围内提供优良的图像质量,有很高的临床应用价值。Objective To compare the image quality and visibility of coronary arteries by dual-source CT (DSCT) and 64-slice CT. Methods 100 patients (group A, 54 male, aged 57.9±11.3 years) with suspected coronary artery disease (CAD) were examined by DSCT. The other 100 patients (group B, 59 male, aged 58.0±11.1 years) with suspected CAD were studied by 64-slice spiral CT. Patients of group B with a heart rate above 70 bpm received oral β-blockers before the scan. Data were retrospectively reconstructed and reviewed by two observers. Image quality was assessed using a 3-point grading scale from excellent (1) to non-assessable (3) and the rate of displayed coronary segments was calculated. The optimal reconstruction phase was registered for each patient. Results The mean heart rates of group A was significantly higher than that of group B [(71±12) bpm vs (61±6) bpm; P〈0.05]. The mean scan time of group A was significantly shorter than that of group B [(7.95±1.01) s vs (11.85±0.89) s; P〈0.01]. In the evaluation of image quality, no significant difference was found between the two groups (1.31±0.53 vs 1.25±0.50; P〉0.05). The rates of diagnostic coronary segments for two groups were 98.9% and 99.1%, respectively (P〉0.05). For patients with heart rates 〈70 bpm, most optimal reconstruction phase ranged from 50% to 80%; For patients with heart rates ≥70 bpm, that ranged from 30% to 80%. Conclusion With high and heart rate independent temporal resolution, DSCT provides high diagnostic image quality in a wide range of heart rates as compared to 64-slice CT and is promising for clinical use.
分 类 号:R814.42[医药卫生—影像医学与核医学] R541.4[医药卫生—放射医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.28