多回不共端高压输电线路互感参数的带电测试  被引量:2

Electrified Measurement of Mutual Inductance for Multicircuit Non-Coterminous H-V Transmission Lines

在线阅读下载全文

作  者:李超 刘建华[1,2,3] 陈允平[1,2,3] 

机构地区:[1]深圳西部电力有限公司 [2]长沙电力学院 [3]武汉水利电力大学

出  处:《长沙水电师院学报(自然科学版)》1997年第2期167-172,共6页

摘  要:提出一种用于带电测量输电线路互感参数的新方法,该方法采用全球卫星定位系统(GPS)送出的时间同步信号作为各测量点的同步采样基准,解决了不共端线路互感参数带电测量的同时性问题.该方法进行了理论上的分析,对用于带电测量互感的计算机系统的硬件组成和软件结构进行了介绍.该装置已成功地用于武汉地区某一走廊内五回220kV线路互感的测量。A new method of mutual-inductance measurement for multicircut non-coterminous H-V transmission lines (MNTL) is presented .This method is able to synchronize the samplings of voltage phasor measurement at an accuracy within 1 usec at two or more remote substation,by means of the global positioning system (GPS),which solve the simultaneous problem of mutual-inductance measurement for MNTL.The mutual-inductance algorithm is deduced and the main components of measurement system is introduced in this paper.This system has been put into practical use in measurement of a 220 kV power network near Wuhan,Hubei prvince,China .

关 键 词:多回不共端线路 互感 带电测量 高压线路 

分 类 号:TM726.1[电气工程—电力系统及自动化]

 