机构地区:[1]山西医科大学公共卫生学院卫生化学教研室,山西太原030001
出 处:《广东微量元素科学》2007年第10期43-45,共3页Trace Elements Science
基 金:山西省自然科学基金资助(No.20041108)
摘 要:研究了铬天青S分光光度法测定铝时,样品消化液中残留高氯酸根的干扰及其消除方法,用阴离子交换树脂将样品消化液中残留的高氯酸根交换去除。结果表明,样品经过阴离子交换树脂柱后,高氯酸根基本去除,不再产生混浊,且铝的回收率达90%。该法简便可行,提高了铝测定的准确度。To study the interference and elimination method of residual ClO^-4 in determination of aluminum by chromium azure S spectrophotometry. Anion-exchange resins chromatography was used to remove ClO^-4 in digested solution of the sample. The results showed that ClO^-4 was eliminated when the solution passed through the column and no turbidity was found. The recovery rate of aluminum was 90%. It conclded the method was simple and effective. The accuracy of the determination was improved.
分 类 号:R115[医药卫生—公共卫生与预防医学] O657.32[理学—分析化学]