检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:徐学君[1] 徐德琴[1] 汪滢[1] 邹若飞[1]
出 处:《中国药事》2007年第11期888-889,893,共3页Chinese Pharmaceutical Affairs
摘 要:考察加药环境与加药器具对输液不溶性微粒的影响。取一次性使用无菌加药器具,分别在净化洁净室和病房治疗室,模拟加药,按《中国药典》,以光阻法测定样品中的不溶性微粒,与未模拟加药的输液比较,在病房治疗室和净化洁净室制备的样品中,≥10μm的不溶性微粒均有显著增加(P<0.05),≥25μm的不溶性微粒均增加不明显(P>0.05);病房治疗室制备的样品与净化洁净室制备的样品比较,≥10μm的不溶性微粒增加显著(P<0.05),≥25μm的不溶性微粒增加不明显(P>0.05)。病房治疗室内加药环境及一次性加药器具可使输液中≥10μm的不溶性微粒明显增加。The impact of pollution of insoluble particles caused by dosing environment and drug infusion devices was studied. Take one--time use of sterile equipment and simulate medicine, respectively in the purification clean room and ward treatment rooms clean room. According to the “Chinese Pharmacopoeia”, samples of insoluble particles by photoresist were determinated, and compared to not simulated drug infusion. In the ward treatment rooms clean room and the purification clean room, the insoluble particles of ≥ 10 μm were significantly increased (P 〈 0. 05), the insoluble particles of ≥ 25 μm were not significant increased (P〉 0.05). Compared the samples of the ward treatment rooms clean room and purification clean room, ≥ 10μm particulate matter increased significantly ( P〈0. 05), and ≥ 25 μm insoluble particles increase was not significant (P〉 0.05). ward drug treatment room plus a one--time environment and increase drug infusion devices enable ≥ 10μ m in the insoluble particles increased significantly.
关 键 词:一次性使用无菌注射器 输液 不溶性微粒