检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李亮[1] 赵忠富[1] 张明杰[1] 孟锦根[2]
机构地区:[1]中国市政工程西南设计研究院,成都610081 [2]四川交通职业技术学院,成都610031
出 处:《给水排水》2007年第12期40-43,共4页Water & Wastewater Engineering
摘 要:根据已建污水处理厂的实际情况,对污泥浓缩池采用加高盖臭气收集方法,对污泥脱水间采用重点区域强化抽吸的臭气收集方法,并采用洗涤-生物滤床联合除臭工艺进行臭气处理;对污泥码头采用喷洒天然植物提取液除臭工艺进行除臭。介绍了除臭工程的设计参数和运行情况,工程实施后,污水处理厂的恶臭状况得到明显改善。For the sludge treatment of Liede Wastewater Treatment Plant, some intensive measures of odor control were applied. High inverted hopper was designed to collect the escaping odor of the sludge thickening tank and strengthening ventilation apparatus were installed at the key location of the sludge dewatering room, then collected odor from both above mentioned locations were sent to the deodorization facility with rinse and biological filtration process. Meanwhile, deodorization device of plant extracts spraying was applied at the sludge dock. The design parameters and operating conditions were introduced in this article. After the implementation of this project, the odor status of the wastewater treatment plant was improved evidently.
分 类 号:TU755[建筑科学—建筑技术科学]