大型火电机组汽机疏水系统优化管理探讨  被引量:5

Discussion on Turbine Drain System Optimal Management in the Large Thermal Power Station

在线阅读下载全文

作  者:陈乔伟 王俊启[1] 李文波[1] 付晨鹏 

机构地区:[1]三门峡华阳发电有限责任公司,河南三门峡472143 [2]河南电力试验研究院,河南郑州450052

出  处:《华中电力》2007年第6期8-11,15,共5页Central China Electric Power

摘  要:针对目前大型火力发电厂生产过程中,汽机疏水系统常见的几种缺陷形式进行归纳、概括,制订对策,开发出了针对疏水阀运行情况的实时监视系统,提出了判断运行中疏水门是否泄漏的方法和思路,为及时发现疏水系统缺陷,进行预防性检修提供了依据,从而大大提高了机组运行的安全性和经济性。Study on main defects of turbine drain system inducing, generalizing and establishing countermeasures in current thermal power plant production process, with a real-time operating condition monitor system of drain valve was developed. A method to judge if leakage exist in a running drain valve was established, which detect drain system defect in time and provide basis to preventive examination and repair, so that security and economy of unit operation was improved greatly.

关 键 词:火力发电厂 疏水系统 缺陷 优化管理 

分 类 号:TK264.1[动力工程及工程热物理—动力机械及工程]

 