检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]上海电器科学研究所(集团)有限公司,上海市200063
出 处:《建筑电气》2007年第12期4-6,共3页Building Electricity
摘 要:隔离电器事关人身安全,必须合理选择与使用。隔离电器应具备三个必要条件(符合动触头在断开位置时的指示要求、应能承受的额定冲击耐受电压值要求和每极进出线端子间允许泄漏电流值要求),才能作为隔离电器使用。还介绍了隔离器和隔离开关的差异和带隔离功能的断路器。Isolating devices are related to personal safety, which should be rationally selected and utilized. Only when the isolating devices possess three prerequisites, which are the indication requirement of the moving contact at the off position, the requirement of the rated impulse withstand voltage to be endured and the requirement of allowable leakage current values between lead-in and out terminals of each electrode, can they be used as isolating devices. Moreover, in this paper, the difference between disconnector and switchdisconnector, the circuit breaker with isolation function are introduced.
关 键 词:隔离器 隔离开关 断路器 ATSE(自动转换开关电器)