酚试剂分光光度法测定饮用水中甲醛  被引量:6

Determination of Formaldehyde in Drinking Water by Hydroxybenzene Reagent Spectrophotometer

在线阅读下载全文

作  者:刘凤海[1] 付宁[1] 纪树贵[1] 

机构地区:[1]牡丹江市疾病预防控制中心,黑龙江牡丹江157021

出  处:《中国卫生工程学》2007年第6期329-330,共2页Chinese Journal of Public Health Engineering

摘  要:目的建立测定饮用水中甲醛方法。方法利用水溶液中甲醛与酚试剂反应生成嗪,嗪在酸性溶液中被高铁离子氧化成蓝绿色化合物,产生颜色与甲醛含量成正比的原理,采用酚试剂分光光度法对饮用水中的甲醛含量进行测定,并与AHMT分光光度法比较。结果本方法的线性范围0.005—0.100mg/L,检出限为5×10^-4mg/L,RSD为1.02%-1.17%,样品加标回收率为96.4%-107.2%。结论该法用于实际水样检测,结果满意。Objective To establish a new method for determination of formaldehyde in drinking water. Methods Qin - material can be formed when formaldehyde in water met hydroxybenzene - reagent, Qin - material in acid solution was oxygened into blue and green compound by high iron ion, moreover, its colour was reliable to the amount of formaldehyde. According to this rule, hydroxybenzene reagent spectrophotometer was used to determine formaldehyde in drinking water and compared with AHMT methed. Results The liner range was 0. 005 -0. 100 mg/L, the detection limit was 5×10^-4 mg/L,RSD was 1.02% - 1.17% and the recovery rates were 96.4% - 107.2%. Conclusion The method is suitable to determine formaldehyde in drinking water.

关 键 词:甲醛 酚试剂 高铁离子 

分 类 号:R123.1[医药卫生—环境卫生学] O657.3[医药卫生—公共卫生与预防医学]

 