作  者:刘永和[1] 黄海燕[1] 

机构地区:[1]邵阳学院生物与化学工程系,湖南邵阳422000

出  处:《分析测试技术与仪器》2007年第4期277-281,共5页Analysis and Testing Technology and Instruments

摘  要:研究催化分光光度法测定水中痕量汞(Ⅱ)的各种干扰因素及消除方法.建立用于测定多组分共存水样中痕量汞(Ⅱ)的催化分光光度加入标准法.以催化分光光度加入标准法测定废水中痕量汞(Ⅱ),其线性范围为3.0×10^-3~8.0×10^-2mg/L,加标回收率97.79%~102.78%,相对标准偏差(RSD)为0.116%,测定结果与原子吸收光谱法相同.This study conducts systematic research into various interference factors and corresponding methods of elimination in the catalytic spectrophotometry for the determination of trace mercury(Ⅱ). The study aims at a new method for the determination of trace mercury (Ⅱ) in waste water with multiple ingredients. The wide linear detection ranges from 3.0× 10^-3 to 8.0× 10^-2 μg/mL. The recovery is 97.79%- 102.78% and the relative standard deviation is 0. 116%. The determination result obtained is the same with that of absorption spectrometry.

关 键 词:催化分光光度  干扰 误差 标准加入 空白底液 