氢化物-原子荧光光谱法测定纺织品中的可萃取铅  被引量:2

Determination of Extractable Lead in Textiles by Hydride Generation-Atomic Fluorescence Spectrometry

在线阅读下载全文

作  者:钱春燕[1] 毕鹏昊[1] 

机构地区:[1]北京市理化分析测试中心,北京100089

出  处:《现代科学仪器》2007年第6期114-116,共3页Modern Scientific Instruments

基  金:北京市科学技术研究院萌芽项目<纺织品中有害物质分析方法的研究>资助。

摘  要:本文建立了测定纺织品模拟酸性汗液中可萃取重金属铅的氢化物-原子荧光光谱法。本法灵敏度高、准确性好、可以在高盐的情况下直接测定铅的含量。在选定的实验条件下,铅浓度与荧光强度在0~50μg/L范围内线性关系良好,方法的检出限为0.003mg/kg,定量下限为0.010mg/kg(以4g样品计),加标回收率99.6%-99.8%,相对标准偏差RSD<2.0%。A hydride generation - atomic fluorescence spectrometry has been developed for the determination of extractable lead in simulated acidic sweat from the textiles. This method is of high sensitivity and good accuracy, and it can directly be used to detect trace lead in high - salt solution. Under an analytical condition optimized, a linear relation between the fluorescence intensity and lead concentration exists in the range of 0 -50μ g/ L. The detection limit of the method is 0. 003mg/kg and quantitative lower limit is 0. 010mg/kg ( as 4g sample weight), the recovery is from 99.6% to 99.8%, and the relative standard deviation is less than 2.0%.

关 键 词:纺织品 可萃取铅 原子荧光法 重金属 

分 类 号:TS107[轻工技术与工程—纺织工程]

 