CT评估隧道式多孔聚乙烯植入材料修复眼眶骨折眶容积的改变  被引量:3

Effect of porous polyethylene channel implants on volume reconstruction of large orbital wall fractures evaluated by computed tomography measurement

在线阅读下载全文

作  者:叶娟[1] 吴涵[1] 高涛[1] 吴仁毅[1] 姚克[1] Sang Yeul Lee 

机构地区:[1]浙江大学医学院附属第二医院眼科中心,杭州310009 [2]韩国延世大学眼科中心

出  处:《中华眼科杂志》2007年第12期1077-1081,共5页Chinese Journal of Ophthalmology

基  金:国家自然科学基金资助项目(30500552);浙江省卫生厅青年人才基金资助项目(2005QN006)

摘  要:目的探讨CT图像和计算机眼眶容积测算程序评估和预测隧道式多孔聚乙烯植入材料(MCI)修复大范围眼眶骨折后眼眶容积改变的临床意义。方法收集单眼大范围眼眶骨折行MCI植入术且手术前、后检查资料完整患者16例,利用计算机Volume程序根据CT图像回顾性定量分析手术前、后眼眶容积的改变,使用Hertel突眼计测量手术前、后的眼球突出度。患者受伤到接受手术的平均时间为(17.4±10.0)d,平均随访时间为9个月。结果手术后CT图像显示全部患者眼眶内前中段MCI位置良好。手术前伤眼眼眶容积[(28.16±4.32)cm^3]与对侧健眼[(23.94±3.47)cm^3]比较,差异有统计学意义(t=3.044,P〈0.01);手术后双眼眼眶容积比较,差异无统计学意义(t=0.069,P〉0.05)。手术前、后眼眶容积的改变量与手术前眼球内陷程度相关(r=0.715,P〈0.01),缓解眼球内陷2mm需手术整复眼眶容积2.86cm^3。结论利用计算机客观测量眼眶容积可对创伤后眼眶骨折的严重程度和可能出现的眼球内陷进行预测。在大范围眼眶骨折导致眼眶容积改变时,在适应证范围内利用MCI行手术治疗是重建眼眶的有效方法,CT图像和计算机眼眶容积测算程序可为手术提供重要数据。Objective To assess the clinical effectiveness of porous polyethylene medpor channel implants (MCI) to restore orbital volume in repairing orbital wall fractures, evaluated by computed tomography(CT) and volume measurement progranun. Methods Sixteen patients with unilateral large orbital fractures were included in this study. Computed tomography (CT) scans were used to obtain computer-based orbital volume measurement to assess the change in orbital volume pre- and post-operatively. Pre- and post-operative enophthalmos were measured using a Hertel exophthalmometer. The average time interval between injury and surgery was (17.4 ± 10.0) days, and the mean follow-up period was 9 months. Results Postoperative CT scan showed that most of the MCI to be well positioned. The orbital volume of the injured orbit was significantly increased [ mean : (28.16 ± 4.32) cm^3 ] as compared with unaffected orbit preoperatively (t = 3. 044, P 〈0.01 ). There was no statistical difference in orbital volume between the injured and normal orbits after orbital reconstruction (t = 0. 069, P 〉 0.05 ). The orbital volume change after reconstructive surgery was significantly positively correlated with the decrease of enophthalmos ( r = 0. 715, P 〈0.01 ). In order to resolve 2 mm enophthalmos, more than 2.86 cm^3 orbital volume augmentation is recommended. Conclusions Orbital volume measurement by CT scan is useful in the post-traumatic evaluation of severity of orbital fractures, and it can help predict the degree of late enophthalmos. Orbital reconstruction with the MCI, when indicated, is recommended.

关 键 词:眶骨折 眼球内陷 眼眶植入物 聚乙烯 体层摄影术 X线计算机 

分 类 号:R686[医药卫生—骨科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象