缩放管混合污垢特性的实验研究  被引量:4

EXPERIMENTAL INVESTIGATION ON THE COMPOSITE FOULING CHARACTERISTICS OF THE CONVERGENT-DIVERGENT TUBE

在线阅读下载全文

作  者:徐志明[1] 张仲彬[2] 詹海波[1] 邵天成[1] 

机构地区:[1]东北电力大学能源与机械工程学院,吉林吉林132012 [2]华北电力大学能源与动力工程学院,河北保定071003

出  处:《工程热物理学报》2008年第2期320-322,共3页Journal of Engineering Thermophysics

基  金:国家重点基础研究发展规划基金项目(No.2007CB206904);国家自然科学基金项目(No.50576009)

摘  要:实验室里进行了缩放管与对应光管管内混合污垢的对比实验,实验工质为加有MgO或CaSO颗粒的人工硬水.实验结果表明:在相同流速、浓度条件下,与对应光管相比,缩放管不仅有较好的阻垢性能,还有较好的传热性能;流速、颗粒浓度和颗粒粒径对混合污垢热阻有较大影响:增大流速、减小颗粒浓度、增大颗粒粒径都会使缩放管混合污垢热阻的渐近值减小。The comparative experiments on the flow resistance and the composite fouling of the convergent-divergent tube and its corresponding plain tube were carried out. The experimental working fluid was the hardness water containing MgO or CaS04 particles. The experimental results show that the convergent-divergent tube has an advantage both in anti-fouling ability and in heat transfer performance over the plain tube under the condition of the same flow velocity and particle concentration. Flow velocity, particle concentration and particle size have great effects on the composite fouling. The asymptotic fouling thermal resistance decreases with the increase of the flow velocity, reduction of the particle concentration and the augment of the particle size.

关 键 词:缩放管 光管 混合污垢 热阻渐近值 

分 类 号:TK124[动力工程及工程热物理—工程热物理]

 