检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李惠成[1] 仵博万[1] 张兵[1] 刘建宁[1]
出 处:《分析测试学报》2008年第1期91-93,共3页Journal of Instrumental Analysis
基 金:甘肃省教育厅基金资助项目(029-04)
摘 要:合成了新荧光试剂水杨醛-2-羧基苯腙(SACPH)。研究了试剂与汞的荧光反应新体系的最适宜条件。在pH6.0的NH4Ac—HCl缓冲溶液中,该试剂与汞离子形成稳定的络合物,金属与试剂的组成比为1:1,λex/em=316.8/456.0nm。所建立汞的荧光分析方法的线性范围为0.5~100.0μg/L,检出限为0.2μg/L,方法成功地应用于矿泉水、纯净水及工业废水中痕量汞的测定。A new fluorescent reagent, salicyladehyde-2-carboxy-phenylhydrazone (SACPH), was synthesized and the optimum conditions for its fluorescence reaction with mercury ions (Hg^2+ ) was studied in detail. Based on the stable Hg^2+- SACPH complex, a spectrofluorimetric method was developed for the determination of Hg^2+ in a buffer solution( NH4Ac - HCl) of pH 6. The fluorescent excitation and emission wavelengths of the complex were at 316.8 nm and 456.0 nm, respectively, The molar ratio of aluminium to reagent was found to be 1 : 1. The linear range of the method was 0.5 - 100.0 μg/L and the detection limit was 0.2 μg/L. The proposed method has been used for the determination of trace mercury in mineral water, purified water and industrial waste water with satisfactory results.
关 键 词:水杨醛-2-羧基苯腙 汞 荧光分析法