阳台吊顶空气/空气热泵机组能效比分析  

Study on Energy Efficiency Ratio of Heat Pump Suspended on Balcony Ceiling

在线阅读下载全文

作  者:安玉翠[1] 马最良 

机构地区:[1]哈尔滨工业大学市政环境工程学院

出  处:《建筑热能通风空调》2007年第6期51-55,共5页Building Energy & Environment

摘  要:设计了一台阳台吊顶暗装空气/空气热泵机组,对其在不同工况下的运行参数和特性进行了数值计算,分析了该机组利用排风和阳台集热后,较常规分体式家用空调的性能变化情况。给出了新机组在不同气候地区,夏季与冬季的制冷/制热能效比的变化情况,并分析了新机组在不同地区的适应性。A heat pump unit suspended on balcony ceiling was designed out, and its operation parameters and performance in different conditions were simulated, and the changes occurred when using this kind of unit which makes use of recycling the energy of exhaust air and the heat collector utilized balcony in winter were analyses, and this changes were compared with regular heat pump room air conditioner. This study gives the changes of EER in different climate areas, and analyses its adaptability in different areas.

关 键 词:排风能量回收 阳台集热 运行性能 

分 类 号:TU831[建筑科学—供热、供燃气、通风及空调工程]

 