检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]云南大唐国际红河发电有限责任公司,云南开远661600 [2]云南火电建设公司调试所,云南昆明650032 [3]北方联合电力公司蒙西电厂,内蒙古鄂尔多斯016100
出 处:《中国电力》2008年第1期63-67,共5页Electric Power
摘 要:与小型循环流化床锅炉相比,300 MWCFB锅炉增加了外置式换热器。介绍外置式换热器的结构、作用及投停过程,并以燃烧理论为基础,结合实际投停外置式换热器的运营经验,对汽温、床温的控制方法进行探讨,并深入论述了外置式换热器在运行中出现问题的原因及处理方法。Compared with small CFB boilers, 300 MW CFB boiler was equipped with external heat exchanger. The structure, function and start-stop process of external heat exchanger were introduced. Based on the combustion theories, combined with the operation experiences of external heat exchanger, the control methods of bed and steam temperature were analyzed. In addition, the reasons and countermeasures for problems in the operation of external heat exchanger were discussed in depth.
分 类 号:TK229.6[动力工程及工程热物理—动力机械及工程]
正在载入数据...