对乙酰基偶氮氯膦光度法测定硅钡镁合金中钡  被引量:4

Spectrophotometric determination of barium in Si-Ba-Mg alloy with p-acetylchlorophosphonazo

在线阅读下载全文

作  者:罗道成[1] 刘俊峰[1] 

机构地区:[1]湖南科技大学化学化工学院,湖南湘潭411201

出  处:《冶金分析》2008年第1期74-76,共3页Metallurgical Analysis

摘  要:研究了对乙酰基偶氮氯膦(CPApA)与钡的显色反应。结果表明,在0.40mol/LH3PO4介质中,CPApA与钡(Ⅱ)反应生成2:1稳定络合物,其最大吸收波长为646nm,表观摩尔吸光系数为1.35×10^5L·mol^-1·cm^-1。钡质量浓度在0~0.80mg/L范围内符合比尔定律。方法已用于硅钡镁合金中钡的测定,结果与重量法相符,实际样品分析结果的相对标准偏差小于3%,加标回收率为97.4%~102.6%。The color reaction of barium with p-acetylchlorophosphonazo (CPApA) was studied. In 0. 40 mol/L H3PO4 medium, p-acetylchlorophosphonazo reacts with barium (Ⅱ) to form a stable 2 : 1 complex, whose maximum absorption wavelength is at 646 nm and apparent molar absorptivity is 1.35×10^5L·mol^-1·cm^-1. Beer's law was obeyed in the range of 0-0.80 mg/L for barium. The barium content in Si-Ba-Mg alloy has been determined by this method, and the results are in good agreement with those provided by gravimetry. The relative standard deviation is less than 3% and the recoveries of samples are between 97.4% and 102.6%.

关 键 词:分光光度法 硅钡镁合金 对乙酰基偶氮氯膦  

分 类 号:TG115.3[金属学及工艺—物理冶金]

 