流动注射化学发光法测定佐米曲谱坦  被引量:2

Chemiluminescence determination of zolmitriptan by flow injection analysis

在线阅读下载全文

作  者:史犇[1] 石杰[1] 吴拥军[2] 刘发光[1] 龚炜[1] 

机构地区:[1]郑州大学化学系,郑州450052 [2]郑州大学公共卫生学院,郑州450052

出  处:《分析试验室》2008年第2期62-64,共3页Chinese Journal of Analysis Laboratory

基  金:河南省科技攻关(0496430006);河南省自然科学基础研究(0411021200);河南省中青年骨干教师项目资助

摘  要:在碱性条件下,佐米曲谱坦对鲁米诺-K3[Fe(CN)6]化学发光体系有较强的抑制作用,据此建立了佐米曲谱坦的流动注射化学发光分析法。该法的化学发光抑制值△I与佐米曲谱坦质量浓度在2.0×10^-6~1.2×10^-4g/mL范围内,呈良好的线性关系,检出限为7.6×10^-7g/mL。对2.5×10^5g/mL佐米曲谱坦测定的相对标准偏差为1.2%(n=11)。方法适用于佐米曲谱坦片中佐米曲谱坦的测定。A new flow injection technique was developed for the determination of zolmitriptan based on the inhibition of the chemiluminescence from Luminal-K3 [ Fe( CN)6 ]-NaOH system. The linear range for Zolmitriptan was 2.0 × 10^-6 1.2× 10^-4 g/mL and the limit of detection was 7.6 × 10^-7 g/mL. The relative standard deviation ( n = 11) was 1.2% for 2.5 × 10^-5 g/mL zolmitriptan. This method was applied to the determination of zolmitriptan in tablets with satisfactory results.

关 键 词:佐米曲谱坦 化学发光抑制 流动注射 

分 类 号:O657.3[理学—分析化学]

 