溴化锂吸收式联供制冷系统用作纺织厂空调的探讨  被引量:1

Discussion on Lithium-bromide absorption chiller applied in air conditioning system for textile mill

在线阅读下载全文

作  者:李新禹[1] 金星[1] 肖树旺 陈杰[1] 方桂珍[1] 

机构地区:[1]天津工业大学纺织学院,天津300160 [2]天纺投资控股有限公司,天津300308

出  处:《天津工业大学学报》2008年第1期27-30,35,共5页Journal of Tiangong University

基  金:天津市教委科技发展基金资助项目(20041205)

摘  要:采用两种能源形式(余热和燃气)的溴化锂吸收式联供制冷系统代替电制冷系统用于纺织厂空调,在夏季全天运行的工况下进行了试验.针对一次能耗率和经济性问题比较了溴化锂制冷系统的应用效果.结果表明,蒸汽型溴化锂吸收式制冷系统的一次能耗率较低,大型直燃型溴化锂吸收式制冷系统具有良好的经济性,两者均优于电制冷系统.The Lithium-bromide absorption chillers which contain two kinds of energy forms (scrap heat and gas) takes the place of the compression system in the air conditioning system of textile mill and the experiment is done under the condition of summer when it is run all day. The Lithium-bromide absorption systems with is carpared compression system in the economic benefit and energy cost ratio. The results show that the energy cost ratio of steam Lithium-bromide absorption system is lower and large-scale of gas Lithium-bromide absorption system is economical.

关 键 词:溴化锂吸收式制冷 纺织厂空调 节能 经济性 

分 类 号:TS108.61[轻工技术与工程—纺织工程] TB69[轻工技术与工程—纺织科学与工程]

 