双色谱柱光离子化气相色谱仪的研制与应用  被引量:1

Development and applications of a two-column photoionization gas chromatograph

在线阅读下载全文

作  者:王荣荣[1] 陆妙琴[1] 马如森[1] 王谦[1] 李绍元[1] 景士廉[1] 

机构地区:[1]中国科学院生态环境研究中心,北京100085

出  处:《分析仪器》1997年第3期35-37,共3页Analytical Instrumentation

基  金:国家自然科学基金

摘  要:The operational principle and the specifications of a portable photoiorization gas chromatograph are described.The chromatograph is composed of two injectors, two columns and one photoionization detector. It has the advantages of wide linear dynamic range, high sensitivity and light weight. The instrument can be used for analyzing trace gases or Vapours in enviromental air and detecting air pollution in working places. Examples of applications are presented.The operational principle and the specifications of a portable photoiorization gas chromatograph are described.The chromatograph is composed of two injectors, two columns and one photoionization detector. It has the advantages of wide linear dynamic range, high sensitivity and light weight. The instrument can be used for analyzing trace gases or Vapours in enviromental air and detecting air pollution in working places. Examples of applications are presented.

关 键 词:光离子化 气相色谱仪 双色谱柱 

分 类 号:TH744.1[机械工程—光学工程]

 