检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张晓庆[1] 刘健慧[1] 朱颖霞[1] 郁庆[1]
机构地区:[1]上海同济大学附属同济医院麻醉科,上海市200065
出 处:《临床麻醉学杂志》2008年第1期17-19,共3页Journal of Clinical Anesthesiology
基 金:上海市卫生局面上项目(044103)
摘 要:目的探讨低位腹主动脉球囊阻断技术在复杂骨盆和盆腔部位手术中的临床应用价值。方法14例复杂骨盆和盆腔部位手术患者,术中采用低位腹主动脉球囊阻断技术,严密观察患者术中血流动力学变化,记录患者术中出血量,术前、术后凝血功能、肾功能的变化,并术后随访72h。结果手术过程顺利,血流动力学稳定。术中失血量50~4000ml,平均失血量928ml,10例患者接受输血,输血量400~4000ml,平均输血量733ml,4例患者未输血。手术前后凝血功能、肾功能指标差异无统计学意义。术后无肢体血栓形成、缺血性坏死及肾功能衰竭等并发症发生。结论低位腹主动脉球囊阻断技术在复杂骨盆和盆腔部位手术操作简便,效果确切,有较好的临床使用价值。Objective To evaluate the clinical application of temporary balloon occlusion of lower abdominal aorta during complicated pelvic surgery. Methods Temporary balloon occlusion of lower abdominal aorta was used in 14 patients with complicated pelvic surgery. The hemodynamics, coagulation function, renal function were monitored and volume of bleeding during operation was recorded. All patients were followed up for 72 hours. Results The operations were all successful and the hemodynamics was stable. The mean volume of bleeding was 928 ml, with a range from 50 to 4 000 ml. Ten patients received blood transfusion (400-4 000 ml), while 4 patients did not. There were no significant changes in coagulation and renal function preoperatively. No postoperative complication of embolism or ischemic necrosis was found in this group of patients. Conclusion Balloon occlusion of lower abdominal aorta technique is simple and effective during complicated pelvic surgery.