检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]State Key Laboratory of Tribology,Tsinghua University
出 处:《Chinese Physics B》2008年第3期1094-1100,共7页中国物理B(英文版)
基 金:Project supported by the Specialized Research Fund for the Doctoral Program of Higher Education of China(Grant No20060003025);the State Key Development Program for Basic Research of China(Grant No2003CB716201)
摘 要:The spread of perfluoropolyether (PFPE) droplets on solid surfaces has been measured from the top-down view through a microscope system. Effects of substrates, molecular weight and end-group functionality on spreading of the PFPE droplets have been studied experimentally and the results were compared with those by molecular dynamics (MD) simulations. Silicon wafer and diamond-like carbon (DLC) substrates were used to study the effect of substrates on spreading. Two types of PFPE, Z-dol and Z-tetraol, with the same chain structure and various molecular weights (2000 and 4000 g/mol) were employed in experiments. Effect of molecular weight has been investigated through comparing the spreading of Z-dol 2000 and Z-dol 4000, and it is found that the increase of molecular weight will decrease the mobility of PFPE. Comparison between spreading of Z-dol and Z-tetraol of the same molecular weight proved that functional end group plays a significant role on the spreading of PFPE, which confirmed the MD simulation results.The spread of perfluoropolyether (PFPE) droplets on solid surfaces has been measured from the top-down view through a microscope system. Effects of substrates, molecular weight and end-group functionality on spreading of the PFPE droplets have been studied experimentally and the results were compared with those by molecular dynamics (MD) simulations. Silicon wafer and diamond-like carbon (DLC) substrates were used to study the effect of substrates on spreading. Two types of PFPE, Z-dol and Z-tetraol, with the same chain structure and various molecular weights (2000 and 4000 g/mol) were employed in experiments. Effect of molecular weight has been investigated through comparing the spreading of Z-dol 2000 and Z-dol 4000, and it is found that the increase of molecular weight will decrease the mobility of PFPE. Comparison between spreading of Z-dol and Z-tetraol of the same molecular weight proved that functional end group plays a significant role on the spreading of PFPE, which confirmed the MD simulation results.
关 键 词:PERFLUOROPOLYETHER SPREADING thin lubricant films hard disk driver
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.112