板式换热器在电厂冷端系统中应用的可行性分析  被引量:5

Feasibility analysis of the plate heat exchange applicated in cold end system

在线阅读下载全文

作  者:周耕宇[1] 

机构地区:[1]华北电力大学能源与动力工程学院,北京102206

出  处:《郑州轻工业学院学报(自然科学版)》2008年第1期63-66,共4页Journal of Zhengzhou University of Light Industry:Natural Science

摘  要:针对电厂凝汽器真空度普遍偏低的情况,提出了以新型的LT板式换热器取代现在的管壳式凝汽器.在对板式换热器和管壳式换热器的性能进行比较的基础上,以某电厂300 MW机组凝汽器为例,对改造方案进行技术经济分析,结果表明方案可行.In view of the low condenser vacuum, a new method that put a plate heater exchange(LT) to replace a tube heater exchange used in power plant condenser was proposed. Based on comparison of the performance of the plate heater exchange and the tube heater exchange, a 300 MW power plant condenser was taken as an example. A reform programme was proposed and the technical and economical analysis was researched, it shows that the scheme is feasible.

关 键 词:凝汽器 管壳式换热器 板式换热器 

分 类 号:TK32[动力工程及工程热物理—热能工程]

 