600MW直冷机组汽包水位采用内置式平衡容器测量技术的改造  被引量:1

Retrofit of Drum's Water Level Measurement Device of 600 MW Direct-Air Cooling Unit by Using Built-in Balancing Vessel

在线阅读下载全文

作  者:李民 秦治国 

机构地区:[1]山西大同发电有限责任公司,山西省大同市037043

出  处:《电力设备》2008年第3期76-78,共3页Electrical Equipment

摘  要:介绍了大同发电公司600MW直接空冷机组在生产过程中,锅炉汽包水位测量存在可靠性低的问题,分析了水位测量装置误差大的原因,提出了将汽包水位测量技术改为采用内置式平衡容器测量技术,介绍了实施情况。改造效果表明,采用内置式平衡容器测量技术后,汽包水位的稳定性和精确度有明显提高。In the operation of 600 M W direct-air cooling unit in Datong power Generation Corp.,the reliability of boiler drum' s,water level measurement was low.Through analysis the cause of larger error of original water level measurement device was defined and the retrofitting scheme was put forward,i.e.,to adopt the built-in balancing vessel measurement technology to retrofit the original drum's water level measurement mode.The retrofit result showed that,after the buillt-in balancing vessel measurement technology was adopted, the stability and accuracy of drum' s water level measurement were obviously raised.

关 键 词:汽包水位 参比水柱 水位差压 内置式平衡容器 

分 类 号:TK223.13[动力工程及工程热物理—动力机械及工程]

 