紧脉与弦脉脉图比较  被引量:7

Comparison of Pulse Graphs Between Taut pulse and Viry Pulse

在线阅读下载全文

作  者:陈冬志[1] 牛欣[2] 董晓英[2] 

机构地区:[1]河北大学医学部,河北保定071000 [2]北京中医药大学,北京100029

出  处:《时珍国医国药》2008年第3期541-542,共2页Lishizhen Medicine and Materia Medica Research

基  金:国家自然科学基金资助项目(No.30371720);国家自然科学基金重点项目(No.60431020)

摘  要:目的探讨紧脉和弦脉两种脉象脉图是否存在差异,寻找两种脉象的客观诊断指标。方法采用脉象仪对紧脉(38例)和弦脉(40例)进行了脉图参数的检测,以35例平脉作为对照组比较。结果紧脉和弦脉主波升支陡峭,脉波上升速度快、斜率大;主波高且宽;重搏前波波幅及高度升高;降中峡高度升高。与平脉比较都具有显著性差异(P<0.001)。与弦脉比较,紧脉重搏前波波幅及降中波波幅增高明显(P<0.01);而主波宽度不如弦脉增加明显(P<0.01)。结论紧脉脉图与弦脉脉图间存在差异。较之弦脉,紧脉外周阻力的加大,更可能是血管功能性收缩增强的结果。Objective To survey the difference of the pulse graphs of taut pulse and vire pulse and its objective diagnostic indexes. Methods With vire pulse (40 cases) and common pulse(35 cases) , sphygmograph was used to test pulse graph parameters of taut pulse (38 cases). Results Main wave of taut pulse and vire pulse was steep;pulse wave went up quickly and its slope rate was large. Main wave was high and wide. The amplitude of wave before repeat wave was increased, the height of dicrotic notch was increased, there was obvious difference compared with the control group( P 〈0. 001 ). The amplitude of wave before repeat wave and dicrotic wave obviously increased compared with vire pulse( P 〈 0.01 ), but its width of main wave didn't increase greatly( P 〈 0.01 ). Condusion There is difference between the pulse graphs of taut and vire pulse. The peripheral resistance of taut pulse is greater than that of vire pulse, which may be caused by strong functional contraction of blood vessel.

关 键 词:紧脉 弦脉 脉图 

分 类 号:R241.1[医药卫生—中医诊断学] R2-03[医药卫生—中医临床基础]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象